Mwen, Tanperati:
Sèlsiyis (C) ak Fahrenheit (F)
Fahrenheit = 32 + Sèlsiyis × 1.8
Sèlsiyis = (Fahrenheit -32) /1.8
Kelvin (K) ak Celsius (C)
Kelvin (K) = Sèlsiyis (C) +273.15
II, konvèsyon presyon:
Mpa、Kpa、pa、bar
1Mpa = 1000Kpa;
1Kpa = 1000pa;
1Mpa = 10bar;
1bar = 0.1Mpa = 100Kpa;
1atmosfè = 101.325Kpa = 1bar = 1kilogram;
1bar = 14.5psi;
1psi = 6.895Kpa;
1 kg/cm2=105=10 mH2O=1 bar=0.1 MPa
1 Pa = 0.1 mmH2O = 0.0001 mH2O
1 mH2O = 104 Pa = 10 kPa
III, vitès van, konvèsyon volim
1CFM = 1.699 M³ / H = 0.4719 l / s
1M³/H = 0.5886CFM
1l/s=2.119CFM
1FPM = 0.3048 m / min = 0.00508 m / s
IV, kapasite refwadisman ak pouvwa:
1KW = 1000 W
1KW = 861Kcal/h = 0.39 P (kapasite refwadisman)
1W = 1 J/s
1USTR = 3024Kcal/h = 3517W (kapasite refwadisman)
1BTU=0.252kcal/h=1055J
1BTU/H=0.252kcal/h
1BTU/H = 0.2931W (kapasite refwadisman)
1MTU/H = 0.2931KW (kapasite refwadisman)
1HP (elektrisite) = 0.75KW (elektrisite)
1KW (elektrisite) = 1.34HP (elektrisite)
1RT (kapasite refwadisman) = 3.517KW (kapasite refwadisman)
1KW (kapasite refwadisman)= 3.412 MBH
1P (kapasite refwadisman).)= 2200kcal/h = 2.56KW
1kcal/h = 1.163W
V,È kondisyoneepesè enstalasyon ak kapasite refwadisman:
1.5mm2 = 12A-20A (2650 ~ 4500W) 1P ~ 2P
2.5mm2 = 20-25A (4500 ~ 5500W) 2P
4mm2 = 25-32A (5500 ~ 7500W) 2P ~ 3P
6mm2 = 32-40A (7500 ~ 8500W) 3P ~ 4P
VI, fòmil kalkil frijidè:
1、Seleksyon valv ekspansyon: tòn frèt + 1.25% alokasyon
2 、 Press pouvwa: 1P = 0.735kW
3 、 frais frigorigènes: refroidissement kapasite (KW) ÷3.516 x 0.58
4、Dlo koule lè pi fre: kapasite refwadisman (KW) ÷ diferans tanperati ÷1.163
5、Refwadisman dlo koule to dlo-refwadi vis machin: Refroidissement kapasite (KW) ×0.86÷ tanperati diferans
6、Refwadisman dlo koule nan machin dlo-refwadi visrefroidissement kapasiteKW + peze pouvwa) ×0.86÷ tanperati diferans
7、Gross chofaj valè QT = QS + QL
8, refwadisman lè: QT = 0.24 * ∝ * L * (h1-h2)
9, siyifikatif chalè lè refwadisman: QS = Cp * ∝ * L * (T1-T2)
10, chalè inaktif nan refwadisman lè: QL = 600 * ∝ * L * (W1-W2)
11,Dlo glasevolim:L/sV1= Q1/(4.187△T1)
12, Volim dlo refwadisman: L/sV2=Q2/(4.187△T2)=(3.516+KW/TR)TR,Q2=Q1+N=TR*3.516+KW/TR*TR=(3.516+KW/TR) *TR
13 、 Efikasite efrijerasyon: EER = kapasite efrijerasyon (Mbtu / h) / konsomasyon pouvwa (KW);COP = Kapasite frijidè (KW) / konsomasyon pouvwa (KW)
14, pèfòmans pasyèl chaj refwadisman: NPLV = 1/(0.01/A+0.42/B+0.45/C+0.12/D)
15 、 Plen chaj aktyèl (twa faz): FLA = N/√3 UCOSφ
16 、 Volim lè fre: Lo = nV
17 、 Airrezèv volim: L=Qs/〔Cp*∝*(T1-T2)〕
18, pouvwa fanatik: N1 = L1 * H1 / (102 * n1 * n2)
19, pouvwa ponp dlo a: N2 = L2 * H2 * r / (102 * n3 * n4)
20 、 Dyamèt tiyo a: D = √4 * 1000L2 / (π * v)
21, zòn kanal: F = a * b * L1 / (1000u)
Tan pòs: 28-Jun-2022