Fòmil kalkil HVAC

微信截图_20220628084907

Mwen, Tanperati:

Sèlsiyis (C) ak Fahrenheit (F)

Fahrenheit = 32 + Sèlsiyis × 1.8

Sèlsiyis = (Fahrenheit -32) /1.8

Kelvin (K) ak Celsius (C)

Kelvin (K) = Sèlsiyis (C) +273.15

II, konvèsyon presyon:

Mpa、Kpa、pa、bar

1Mpa = 1000Kpa;

1Kpa = 1000pa;

1Mpa = 10bar;

1bar = 0.1Mpa = 100Kpa;

1atmosfè = 101.325Kpa = 1bar = 1kilogram;

1bar = 14.5psi;

1psi = 6.895Kpa;

1 kg/cm2=105=10 mH2O=1 bar=0.1 MPa

1 Pa = 0.1 mmH2O = 0.0001 mH2O

1 mH2O = 104 Pa = 10 kPa

III, vitès van, konvèsyon volim

1CFM = 1.699 M³ / H = 0.4719 l / s

1M³/H = 0.5886CFM

1l/s=2.119CFM

1FPM = 0.3048 m / min = 0.00508 m / s

IV, kapasite refwadisman ak pouvwa:

1KW = 1000 W

1KW = 861Kcal/h = 0.39 P (kapasite refwadisman)

1W = 1 J/s

1USTR = 3024Kcal/h = 3517W (kapasite refwadisman)

1BTU=0.252kcal/h=1055J

1BTU/H=0.252kcal/h

1BTU/H = 0.2931W (kapasite refwadisman)

1MTU/H = 0.2931KW (kapasite refwadisman)

1HP (elektrisite) = 0.75KW (elektrisite)

1KW (elektrisite) = 1.34HP (elektrisite)

1RT (kapasite refwadisman) = 3.517KW (kapasite refwadisman)

1KW (kapasite refwadisman= 3.412 MBH

1P (kapasite refwadisman).= 2200kcal/h = 2.56KW

1kcal/h = 1.163W

V,È kondisyoneepesè enstalasyon ak kapasite refwadisman:

1.5mm2 = 12A-20A (2650 ~ 4500W) 1P ~ 2P

2.5mm2 = 20-25A (4500 ~ 5500W) 2P

4mm2 = 25-32A (5500 ~ 7500W) 2P ~ 3P

6mm2 = 32-40A (7500 ~ 8500W) 3P ~ 4P

VI, fòmil kalkil frijidè:

1、Seleksyon valv ekspansyon: tòn frèt + 1.25% alokasyon

2 、 Press pouvwa: 1P = 0.735kW

3 、 frais frigorigènes: refroidissement kapasite (KW) ÷3.516 x 0.58

4、Dlo koule lè pi fre: kapasite refwadisman (KW) ÷ diferans tanperati ÷1.163

5、Refwadisman dlo koule to dlo-refwadi vis machin: Refroidissement kapasite (KW) ×0.86÷ tanperati diferans

6、Refwadisman dlo koule nan machin dlo-refwadi vis:(refroidissement kapasiteKW + peze pouvwa) ×0.86÷ tanperati diferans

7、Gross chofaj valè QT = QS + QL

8, refwadisman lè: QT = 0.24 * ∝ * L * (h1-h2)

9, siyifikatif chalè lè refwadisman: QS = Cp * ∝ * L * (T1-T2)

10, chalè inaktif nan refwadisman lè: QL = 600 * ∝ * L * (W1-W2)

11,Dlo glasevolimL/sV1= Q1/(4.187△T1)

12, Volim dlo refwadisman: L/sV2=Q2/(4.187△T2)=(3.516+KW/TR)TR,Q2=Q1+N=TR*3.516+KW/TR*TR=(3.516+KW/TR) *TR

13 、 Efikasite efrijerasyon: EER = kapasite efrijerasyon (Mbtu / h) / konsomasyon pouvwa (KW);COP = Kapasite frijidè (KW) / konsomasyon pouvwa (KW)

14, pèfòmans pasyèl chaj refwadisman: NPLV = 1/(0.01/A+0.42/B+0.45/C+0.12/D)

15 、 Plen chaj aktyèl (twa faz): FLA = N/√3 UCOSφ

16 、 Volim lè fre: Lo = nV

17 、 Airrezèv volim: L=Qs/〔Cp*∝*(T1-T2)〕

18, pouvwa fanatik: N1 = L1 * H1 / (102 * n1 * n2)

19, pouvwa ponp dlo a: N2 = L2 * H2 * r / (102 * n3 * n4)

20 、 Dyamèt tiyo a: D = √4 * 1000L2 / (π * v)

21, zòn kanal: F = a * b * L1 / (1000u)


Tan pòs: 28-Jun-2022